Hemodynamics, fluids & transfusion

Prognostic value of capillary refill time in adult patients: a systematic review with meta-analysis

Crit CarePublished Systematic review and meta-analysis

Authors' conclusion

CRT poorly predicted death and adverse events in patients at risk or established acute circulatory failure. Its accuracy is greater when high-quality CRT measurement is performed.

Study context

Population
Adults at risk of or with confirmed acute circulatory failure
Participants
60,656 adults · 23 studies
Comparison
Abnormal capillary refill time (CRT) as predictor of death or adverse events
Outcome
Ability of abnormal CRT to predict death in patients with acute circulatory failure
Methodological detailsrandom-effects model
  • Random-effects model

Pooled result

As reported in the abstract

Abnormal CRT predicting death in acute circulatory failure (primary analysis, 13 studies)

Pooled AUC ROC

0.66 (95%CI [0.59; 0.76])

Pooled sensitivity

54% (95%CI [43; 64])

Pooled specificity

72% (95%CI [55; 84])

Pooled diagnostic OR

3.4 (95%CI [1.4; 8.3])

Further pooled results

CRT predicting death or adverse events in patients at risk or with confirmed acute circulatory failure (secondary analysis, 23 studies)

Pooled AUC ROC
0.69 (95%CI [0.65; 0.74])

Prognostic value of CRT vs lactate

Not significantly different

High-quality CRT measurement

Associated with greater accuracy

Original publication