Respiratory failure & ventilation

Protective mechanical ventilation controlled by the real-time mechanical power measurement

J Clin Monit ComputPublished Randomised controlled trial

Authors' conclusion

Although real-time MP measurement is feasible, there was no significant difference in MP between the control and intervention groups with low MP in both groups.

Study context

Population
Adults on mechanical ventilation (MV) (with or without ECMO) with acute respiratory failure, ECMO Centre Ostrava, Czech Republic, March 2023–March 2024randomized
Participants
33 adults
Comparison
Real-time mechanical power (MP) displayed to physician vs MP concealed
Methodological detailssingle-centre
  • Single-centre

Primary result

As reported in the abstract

Mechanical power (MP)
  • No significant difference between control and intervention groups

Further findings

MP, all patients (geometric method and simplified Becher's formula)

Median MPGeom (maximum 15.2 J/min)
3.22 J/min
MPBecher (maximum 18.4 J/min)
5.94 J/min
Weak but significant correlation between MPGeom and MPBecher
P = 0.0001

MP, day vs night

Highly significant difference between day and night, with higher MP at night

Original publication

Protective mechanical ventilation controlled by the real-time mechanical power measurement. J Clin Monit Comput. Published 11 October 2025. doi:10.1007/s10877-025-01369-w