Neuroanesthesia & neurocritical care

Reduction of the acquisition time needed to obtain somatosensory evoked potentials by estimation of the required averaging sweep count by an algorithm

J Clin Monit ComputPublished Prospective methodological study

Authors' conclusion

The proposed algorithm allowed sweep count and acquisition time reduction in roughly 90% of all patients for mSEPs and in 70% of all patients for tSEPs.

Study context

Population
Patients undergoing spinal surgery with intraoperative SEP monitoring, Department of Neurosurgery
Participants
30 patients
Exposure
Algorithm-determined minimal sweep count vs standard 200 sweeps
  • mSEPsn = 15
  • tSEPsn = 15
Outcome
Median necessary sweep count to obtain reproducible evoked potentials (below 200)

Main finding

As reported in the abstract

Required sweep count
GroupValueMean sweep count
mSEPs93.3%56 ± 51
tSEPs73.3%106 ± 70

Value

mSEPs93.3%
tSEPs73.3%

Mean sweep count

mSEPs56 ± 51
tSEPs106 ± 70

Observational data: associations, not effects.

Further findings

Calculated mean time to average the potentials

mSEPs: reduced from 48.8s to 13.7s
tSEPs: reduced from 48.8s to 25.9s

Original publication

Reduction of the acquisition time needed to obtain somatosensory evoked potentials by estimation of the required averaging sweep count by an algorithm. J Clin Monit Comput. Published 11 September 2024. doi:10.1007/s10877-024-01217-3

Composed by AI from the published abstract and checked against it. How Briefs are made →