Hemodynamics, fluids & transfusion
Renal Replacement Therapy in Cardiogenic Shock supported by microAxial Flow Pumps: A European multicentre study
Authors' conclusion
In this large European registry of mAFP-supported CS, RRT was frequent and associated with increased 180-day mortality and greater shock severity.
Study context
- Population
- Patients with cardiogenic shock (CS) supported with microaxial flow pumps (mAFP) across 11 European centresincluded, of 1043 patients
- Participants
- 972 patients
- Exposure
- Renal replacement therapy (RRT) vs no RRT
- Outcome
- 180-day all-cause mortality (with survival censored at heart transplantation or durable left ventricular assist device implantation)
- Follow-up
- 180 days
Methodological details1:1 propensity score-matched cohort, multivariable logistic regression
- 1:1 propensity score-matched cohort
- Multivariable logistic regression
Main finding
As reported in the abstract
180-day all-cause mortality…
RRT vs NO RRTHR for all-cause mortality (95% CI)P value
After propensity score matching
1.48(1.14–1.92)
P < 0.01Before propensity score matching
2.04(1.67–2.49)
P < 0.01- 180-day all-cause mortality (with survival censored at heart transplantation or durable left ventricular assist device implantation)
- restricted mean survival difference −25.5 days (95% CI - 39.9 to −10.2)
Observational data: associations, not effects.
Further findings
Factors associated with RRT
| aOR (95% CI) | ||
|---|---|---|
| BMI ≥ 30 kg/m²Multivariable logistic regression | 1.69 (1.15–2.46) | |
| Norepinephrine useMultivariable logistic regression | 1.72 (1.19–2.49) | |
| Lactate ≥4 mmol/L at implantationMultivariable logistic regression | 1.56 (1.11–2.20) | |
| 0.512Adjusted odds ratio (log scale) |
| Outcome | aOR (95% CI) | |
|---|---|---|
| Factors associated with RRTBaseline serum creatinine (per 20 µmol/L increase) · multivariable logistic regression | 1.18 (1.12–1.24) | |
| 0.512Adjusted odds ratio (log scale) |
- Factors associated with RRT — Required RRT
- 340 (35.0%)
Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.
Original publication
Renal Replacement Therapy in Cardiogenic Shock supported by microAxial Flow Pumps: A European multicentre study. Anaesth Crit Care Pain Med. Published 14 November 2026. doi:10. 1016/ j. accpm. 2026. 101992
Composed by AI from the published abstract and checked against it. How Briefs are made →