Cardiac arrest & resuscitation

The impact of real-time feedback on ventilation quality during out-of-hospital cardiac arrest: A before-and-after study

ResuscitationPublished Before-and-after study

Authors' conclusion

The use of real-time feedback was associated with an increased proportion of ventilations that were compliant with pre-defined targets during cardiac resuscitation.

Study context

Population
Adult out-of-hospital cardiac arrest (OHCA) patients where the ZOLL Accuvent device measured ventilation rate and volume, Ontario, Canada
Participants
412 participants
Comparison
Real-time ventilation feedback vs no feedback
  • With feedbackn = 221
  • Without feedbackn = 191reference
Outcome
Proportion of each case compliant with pre-defined ventilation targets (rate and volume)
Methodological detailsfour paramedic services
  • Four paramedic services

Main finding

As reported in the abstract

Compliance with ventilation rate and volume targets
  • Significant improvements in both ventilation rate and volume with real-time feedback vs without

Further findings

Ventilation compliance by advanced airway use; intra-arrest vs post-cardiac arrest

No differences in ventilation compliance with or without advanced airways, or intra-arrest or post-cardiac arrest

Original publication

The impact of real-time feedback on ventilation quality during out-of-hospital cardiac arrest: A before-and-after study. Resuscitation. Published 18 September 2024. doi:10.1016/j.resuscitation.2024.110381