Authors' conclusion

These results show that the degree of thrombocytopenia depends on MCS device type and is reversible.

Study context

Population
Patients on temporary mechanical circulatory support (MCS), excluding platelet transfusions, bleeding complications, etc.77 analysed
Participants
337 patients
Exposure
Temporary MCS strategies: Impella 5.5, VV ECMO, VA ECMO, Intra-aortic Balloon Pump (IABP), Centrimag Biventricular Assist Device (BIVAD)
Outcome
Mean percent platelet drop on MCS implantation
Methodological detailsrepeated measure mixed effect and linear regression models
  • Repeated measure mixed effect and linear regression models

Main finding

As reported in the abstract

Mean percent platelet drop on implantation
GroupValuep
VA ECMOmean −69.6%p < 0.001
VV ECMOmean −40.9%p < 0.001
Impella 5.5mean −20.9%p = 0.01
IABPmean −28.3%p = 0.01
Centrimag BIVADmean −6.5%p = 0.61

Value

VA ECMOmean −69.6%
VV ECMOmean −40.9%
Impella 5.5mean −20.9%
IABPmean −28.3%
Centrimag BIVADmean −6.5%

p

VA ECMOp < 0.001
VV ECMOp < 0.001
Impella 5.5p = 0.01
IABPp = 0.01
Centrimag BIVADp = 0.61

Observational data: associations, not effects.

Further findings

OutcomeValues
Platelet recovery after MCS explantationRecovery to or above baselineVA ECMO +107.0% · p p = 0.42 · Impella 5.5 +117.2% · p p = 0.28 · IABP +108.3% · p p = 0.37 · VV ECMO 163.3% · p p = 0.01* · Centrimag BIVAD +100.1% · p p = 0.99

Original publication

The impact of temporary mechanical circulatory support strategies on thrombocytopenia. J Crit Care. Published 23 November 2022. doi:10.1016/j.jcrc.2022.154216

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.