Cardiothoracic & vascular anesthesia

The Use of Contrast May Improve Aortic Valve Assessment During Transesophageal Echocardiography

J Cardiothorac Vasc AnesthPublished Method comparison study

Authors' conclusion

This discrepancy is significant and could affect the decision to replace the aortic valve.

Study context

Population
Patients undergoing surgical aortic valve replacement for a stenotic valve, tertiary hospital
Participants
30 consecutive patients
Exposure
Contrast vs noncontrast transesophageal echocardiography (TEE) Doppler assessment of the aortic valve
Outcome
Aortic valve area
Methodological detailssingle-centre, retrospective review, consecutive patients, Bland-Altman analysis
  • Single-centre
  • Retrospective review
  • Consecutive patients
  • Bland-Altman analysis

Main finding

As reported in the abstract

Without contrast agent, aortic valve area overestimated vs TTE

0.26 cm²

Observational data: associations, not effects.

Further findings

Peak and mean aortic valve gradients without contrast

Peak gradient underestimated (mmHg)
19
Mean gradient underestimated (mmHg)
11
  • p value <0.001

Pulse-wave Doppler V1 velocity of the left ventricular outflow tract (LVOT)

Not affected by contrast

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

The Use of Contrast May Improve Aortic Valve Assessment During Transesophageal Echocardiography. J Cardiothorac Vasc Anesth. Published 22 February 2023. doi:10.1053/j.jvca.2023.02.023

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.