Cardiothoracic & vascular anesthesia

Three-Dimensional Echocardiographic Approach to Mitral Valve After Transcatheter Edge-to-Edge Repair

Anesth AnalgPublished Retrospective cohort study

Authors' conclusion

In this retrospective cohort study, we demonstrated excellent agreement between TEE-3DOA-derived MVA under GA and TTE PHT-derived MVA in awake patients, but not between TEE versus TTE PHT.

Study context

Population
Adults with severe mitral regurgitation undergoing transcatheter edge-to-edge repair (TEER) (MitraClip, Abbott)
Participants
20 adults
Exposure
Transesophageal echocardiography (TEE) 3DOA and TEE pressure half-time (PHT) under general anesthesia (GA) vs TTE PHT in awake patients for post-TEER MVA
Outcome
Agreement of MVA measurements (Bland-Altman 95% limits of agreement and Lin's concordance correlation coefficient)
Methodological detailsmethod-agreement study
  • Method-agreement study

Main finding

As reported in the abstract

Agreement of post-TEER MVA measurements with TTE PHT
TEE 3DOA · excellent
concordance correlation coefficient 0.95 (95% CI 0.86–0.98)
TEE 3DOA
Bland-Altman upper limit of agreement 0.26 (95% CI 0.12–0.4)
TEE PHT · weak
concordance correlation coefficient 0.46 (95% CI 0.02–0.75)
TEE PHT · much broader limits of agreement
Bland-Altman lower limit of agreement −1.6 (95% CI −2.19 to −1.02)
TEE PHT
Bland-Altman upper limit of agreement 1.43 (95% CI 0.84–2.01)

Observational data: associations, not effects.

Original publication

Three-Dimensional Echocardiographic Approach to Mitral Valve After Transcatheter Edge-to-Edge Repair. Anesth Analg. Published 15 December 2025. doi:10.1213/ane.0000000000007756

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.