Obstetric anesthesia

Ventilatory Parameters in Obstetric Patients With COVID-19 and Impact of Delivery: A Multicenter Prospective Cohort Study

ChestPublished Prospective cohort study

Authors' conclusion

Delivery was induced mainly for maternal reasons, but did not change ventilatory parameters other than Pao2 to Fio2 ratio.

Study context

Population
Pregnant and postpartum patients with COVID-19 requiring advanced ventilatory support in the ICU
Participants
91 participants · 21 ICUs
Exposure
Ventilatory parameters before vs after delivery
Outcome
Ventilatory parameters and impact of delivery on them
Methodological detailsmulticentre
  • Multicentre

Main finding

As reported in the abstract

Respiratory parameters before and after delivery
GroupValuePlateau pressureDriving pressureMedian static compliancePaO2/FiO2
Before deliverymean 25.6 (SD 6.6) cm H2O25.6 ± 6.6 cm H2O13.6 ± 4.2 cm H2O28 mL/cm H2O (IQR, 22.5-39)134 (IQR, 100-230)
After delivery ≤ 2 hmean 24 (SD 6.7) cm H2O24 ± 6.7 cm H2O12.9 ± 3.9 cm H2O30 mL/cm H2O (IQR, 24.5-44)168 (IQR, 136-185)
After delivery 24 hmean 24.6 (SD 5.2) cm H2O24.6 ± 5.2 cm H2O13 ± 4.4 cm H2O30 mL/cm H2O (IQR, 24.5-44)192 (IQR, 132-232.5)

Value

Before deliverymean 25.6 (SD 6.6) cm H2O
After delivery ≤ 2 hmean 24 (SD 6.7) cm H2O
After delivery 24 hmean 24.6 (SD 5.2) cm H2O

Plateau pressure

Before delivery25.6 ± 6.6 cm H2O
After delivery ≤ 2 h24 ± 6.7 cm H2O
After delivery 24 h24.6 ± 5.2 cm H2O

Driving pressure

Before delivery13.6 ± 4.2 cm H2O
After delivery ≤ 2 h12.9 ± 3.9 cm H2O
After delivery 24 h13 ± 4.4 cm H2O

Median static compliance

Before delivery28 mL/cm H2O (IQR, 22.5-39)
After delivery ≤ 2 h30 mL/cm H2O (IQR, 24.5-44)
After delivery 24 h30 mL/cm H2O (IQR, 24.5-44)

PaO2/FiO2

Before delivery134 (IQR, 100-230)
After delivery ≤ 2 h168 (IQR, 136-185)
After delivery 24 h192 (IQR, 132-232.5)
Plateau pressure across time points
P = 0.59
Driving pressure across time points
P = 0.69
Static compliance across time points
P = 0.058
PaO2/FiO2 across time points
P = 0.022

Observational data: associations, not effects.

Further findings

Risk factor for invasive mechanical ventilation (IMV): SOFA24 score

OR (95% CI)P value
SOFA24 scoreOnly risk factor1.97 (1.29–2.99)P = 0.001

Risk factors for maternal mortality

OR (95% CI)P value
BMI1.10 (1.006–1.204)P = 0.037
Comorbidities4.15 (1.212–14.20)P = 0.023

Risk factors for fetal or neonatal mortality

OR (95% CI)P value
Gestational age at delivery0.67 (0.52–0.86)P = 0.002
SOFA24 score1.53 (1.13–2.08)P = 0.006

Respiratory parameters at IMV onset (pregnant patients)

Plateau pressure, mean ± SD
24.3 ± 4.5 cm H2O
Driving pressure, mean ± SD
12.5 ± 3.3 cm H2O
Median static compliance
31 mL/cm H2O (IQR, 26-40)
Median PaO2/FiO2
142 (IQR, 110-176)

Maximal ventilatory support

IMV
69 (76%)
HFNC
20 (22%)
NIV
2 (2%)
  • 63 (69%) delivered in ICU

Reasons for induced delivery

Maternal
43 of 71 (60.5%)
Maternal and fetal
21 of 71 (29.5%)
Fetal
7 of 71 (9.9%)
Continued pregnancy after ICU discharge
14 (22.2%)

Original publication

Ventilatory Parameters in Obstetric Patients With COVID-19 and Impact of Delivery: A Multicenter Prospective Cohort Study. Chest. Published 17 October 2022. doi:10.1016/j.chest.2022.10.010

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.