Anesthetic drugs & techniques

Adjustment of positive end‐expiratory pressure based on body mass index during general anaesthesia: a randomised controlled trial*

AnaesthesiaPublished Randomised controlled trial

Authors' conclusion

In patients without major pulmonary disease who were undergoing non-cardiothoracic surgeries with tracheal intubation, adjusting PEEP based on a calculation of BMI/3 improved lung mechanics and reduced postoperative loss of lung aeration.

Study context

Population
Adults undergoing surgery under GA with tracheal intubation
Participants
60 adults
Comparison
PEEP set by BMI vs standard PEEP 5 cmH2O
Methodological detailspatient-blinded, single-centre, superiority, two parallel groups
  • Patient-blinded
  • Single-centre
  • Superiority
  • Two parallel groups

Primary result

As reported in the abstract

Driving pressure

P = 0.027

Further findings

Respiratory system compliance

P = 0.020

Postoperative loss of lung aeration (lung ultrasound)

Reduced in the BMI/3 group

Supplemental oxygen, new atelectasis, SpO2 on PACU arrival

Less supplemental oxygen, less new atelectasis and higher oxygen saturation in the BMI-adjusted group

Original publication

Adjustment of positive end‐expiratory pressure based on body mass index during general anaesthesia: a randomised controlled trial*. Anaesthesia. Published 23 June 2025. doi:10.1111/anae.16656