Haemodynamics, fluids & transfusion

Assessing fluid responsiveness in mechanically ventilated patients with intra-abdominal hypertension: a two-center, prospective, observational study

Crit CarePublished Diagnostic accuracy study

Authors' conclusion

In patients with IAH, the limited diagnostic value of PLR for fluid responsiveness may be related to persistently negative CVP-IAP gradients in false-negative cases, whereas EEO and mini-fluid challenge remain reliable alternatives.

Study context

Population
Mechanically ventilated ICU patients monitored by transpulmonary thermodilution receiving a 500-mL fluid challenge
Participants
88 participants · 2 intensive care units (ICUs)
Comparison
Intra-abdominal hypertension (IAH)- vs IAH +
  • IAH-n = 44reference
  • IAH +n = 44
Outcome
Diagnostic accuracy (AUROC) of PLR, EEO and mini-fluid challenge for fluid responsiveness (≥ 15% CI increase after 500 mL)
Methodological detailsprospective, observational, two-center
  • Prospective
  • Observational
  • Two-center

Performance

As reported in the abstract

AUROC for detecting fluid responsiveness
Test or modelPassive leg raising (PLR) AUROCEnd-expiratory occlusion (EEO) AUROCMini-fluid challenge AUROC
IAH-0.96 (0.87-1.00)0.95 [0.87-1.00]0.94 [0.87-1.00]
IAH +0.71 (0.56-0.87)0.89 [0.80-0.97]0.90 [0.79-1.00]

Passive leg raising (PLR) AUROC

IAH-0.96 (0.87-1.00)
IAH +0.71 (0.56-0.87)

End-expiratory occlusion (EEO) AUROC

IAH-0.95 [0.87-1.00]
IAH +0.89 [0.80-0.97]

Mini-fluid challenge AUROC

IAH-0.94 [0.87-1.00]
IAH +0.90 [0.79-1.00]
  • IAH + vs IAH-: P = 0.009
  • IAH + vs IAH-: P = 0.332 — similar
  • IAH + vs IAH-: P = 0.514 — similar

Further findings

Baseline IAP

P < 0.001

CI increase during PLR (responders)

P < 0.001

PLR positive IAH- 24/25 responders

CI increase after volume expansion (responders)

P = 0.907

CVP-IAP gradient during PLR in IAH + (16 false negatives, 6 true positives)

True positives: from −2.4 ± 4.0 to + 2.2 ± 2.7 mmHg (reversed)
P = 0.014
False negatives: from −6.3 ± 3.7 to −1.4 ± 3.4 mmHg (remained negative)
P < 0.001
  • Both with negative baseline CVP-IAP gradients

Original publication

Assessing fluid responsiveness in mechanically ventilated patients with intra-abdominal hypertension: a two-center, prospective, observational study. Crit Care. Published 17 July 2026. doi:10.1186/s13054-026-06191-7

Composed by AI from the published abstract and checked against it. How Briefs are made →