Both the extended neck position and insertion of a supraglottic airway device increases the height of the cricothyroid membrane in females. A prospective observational study

BJA OpenPublished Prospective observational study

Authors' conclusion

Both neck extension and the insertion of an i-gel® increased the sagittal height of the CTM.

Study context

Population
Adult females having minor gynaecological surgery under GA, suitable for an supraglottic airway device (SAD)
Participants
40 females · 160 images
Exposure
Neutral vs extended neck position, before and after i-gel® insertion
Outcome
Sagittal cricothyroid membrane (CTM) height on ultrasound
Methodological detailsblinded assessor
  • Blinded assessor

Main finding

As reported in the abstract

CTM height
Significant difference in cricothyroid membrane (CTM) height between the groups
P<0.001
Extended neck position: increase over neutral position
10%
I-gel® plus neck extension: increase over neutral position
26%
I-gel® plus neck extension: CTM long enough to accommodate a size 6.0 tracheal tube
100%