Respiratory failure & ventilation

Breath metabolomics for diagnosis of acute respiratory distress syndrome

Crit CarePublished Diagnostic accuracy study

Authors' conclusion

An exhaled breath metabolomics-based classifier has moderate diagnostic accuracy for ARDS but was not sufficiently accurate for clinical use, even after combination with a clinical prediction score.

Study context

Population
Critically ill invasively ventilated intensive care unit (ICU) patients
Participants
499 participants · 2 centres
Comparison
Derivation vs Validation
  • Derivationn = 357
  • Validationn = 142
Outcome
Diagnostic accuracy of breath metabolites for ARDS
Methodological detailstwo-centre, observational, derivation and validation cohorts
  • Two-centre
  • Observational
  • Derivation and validation cohorts

Performance

As reported in the abstract

Area under the receiver operating characteristics curve (AUROCC) of classifier (5 metabolites) for ARDS
Test or modelValueAUC
Derivation17%0.71 (CI 0.63-0.78)
Validation33%0.63 (CI 0.52-0.74)

Value

Derivation17%
Validation33%

AUC

Derivation0.71 (CI 0.63-0.78)
Validation0.63 (CI 0.52-0.74)

Further findings

Classifier combined with lung injury prediction score (LIPS)

Combining breath test with LIPS does not significantly enhance diagnostic performance

Original publication

Breath metabolomics for diagnosis of acute respiratory distress syndrome. Crit Care. Published 23 March 2024. doi:10.1186/s13054-024-04882-7

Composed by AI from the published abstract and checked against it. How Briefs are made →