Regional anesthesia

Clinical Utility of Ultrasonographic Guidance for Arterial Catheterization in Patients with Obesity: A Randomized Controlled Trial

J Cardiothorac Vasc AnesthPublished Randomised controlled trial

Authors' conclusion

The results of this study do not support the routine use of ultrasonography during radial arterial catheterizations for obese adults when junior practitioners perform the procedure.

Study context

Population
Adults with body mass index (BMI) ≥30 kg/m²; catheterization by anesthesia residents
Participants
80 adults
Comparison
Ultrasound guidance vs Conventional palpation
Primary endpoint
First-attempt success rate of arterial catheterization
Methodological detailsprospective, single tertiary center
  • Prospective
  • Single tertiary center

Primary result

As reported in the abstract

P = 0.6331

Further findings

OutcomeMean difference (mm) (95% CI)P value
Radial artery skin-to-artery distance by BMI groupBMI 40-49 kg/m² vs BMI 30-39 kg/m²1.0 (0.4–1.7)P = 0.0029
Radial artery skin-to-artery distance by BMI groupBMI ≥50 kg/m² vs BMI 30-39 kg/m²1.5 (0.6–2.4)P = 0.0015

Radial artery skin-to-artery distance by BMI group

Similar findings for the brachial artery

Association of BMI with first-attempt success and time to successful catheterization

BMI inversely associated with first-attempt success rates
P = 0.0145
BMI positively associated with time to successful catheterization
P = 0.0271

Safety

Vascular complications · did not differ significantly

P = 0.6531

Original publication

Clinical Utility of Ultrasonographic Guidance for Arterial Catheterization in Patients with Obesity: A Randomized Controlled Trial. J Cardiothorac Vasc Anesth. Published 8 August 2024. doi:10.1053/j.jvca.2024.08.006

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.