Organ support & nutrition

Comparison of two different bicarbonate replacement fluids during continuous veno-venous hemofiltration (CVVH) with RCA: a prospective, randomized, controlled trial

Intensive Care MedPublished Randomised controlled trial

Authors' conclusion

LBF showed significantly lower rates of pH and HCO3- excursions compared to HBF and no significant differences to the pH normalization in acidotic patients were observed.

Study context

Population
Patients on CVVH with regional citrate anticoagulationcrossover
Participants
88 patients
Comparison
HBF vs LBF
Primary endpoint
At least one pH/HCO3- excursion outside standard values
Follow-up
96 h (two 48-h phases)
Methodological detailsprospective, open-label, cross-over, single-center
  • Prospective
  • Open-label
  • Cross-over
  • Single-center

Primary result

As reported in the abstract

≥1 pH and HCO3- excursion (levels outside standard values)

pH, first phase

pH, second phase

HCO3-, first phase

HCO3-, second phase

Adjusted OR for ≥1 pH excursion
1.78 (95% CI 1.12-2.82; p = 0.015)
Adjusted OR for ≥1 HCO3- excursion
3.60 (95% CI 2.16-5.99; p < 0.001)

Further findings

OutcomeP value
Time to normalization (pH in acidotic patients; HCO3- in low HCO3-), first phaseHBF vs LBF · pHP = 0.102
Time to normalization (pH in acidotic patients; HCO3- in low HCO3-), first phaseHBF vs LBF · HCO3-P = 0.468

Time to normalization (pH in acidotic patients; HCO3- in low HCO3-), first phase

Did not differ significantly between HBF and LBF

Original publication

Comparison of two different bicarbonate replacement fluids during CVVH with RCA: a prospective, randomized, controlled trial. Intensive Care Med. Published 17 November 2025. doi:10.1007/s00134-025-08175-7

Composed by AI from the published abstract and checked against it. How Briefs are made →