Anesthetic drugs & techniques

Cortical, subcortical, brainstem and autonomic responses to nociception under total intravenous anesthesia

J Clin AnesthPublished Observational study

Authors' conclusion

PRD, HR, and BIS correlated with varying levels of remifentanil, with PRD exhibiting the strongest correlation. When CE remifentanil are low, noxious stimuli are more likely to dilate the pupil and be detected in the EEG.

Study context

Population
Patients under GA with TCI of propofol and remifentanil
Exposure
NOL, Analgesia Nociception Index (ANI), Pupillary Reflex Dilation (PRD), raw and processed EEG (BIS, qCON, qNOX) and HR responses to standardized tetanic stimulation under varying propofol and remifentanil concentrations
Outcome
Performance of nociception monitors in response to standardized tetanic stimulation and correlation with varying remifentanil concentrations

Main finding

As reported in the abstract

  • ANI, BIS, HR, NOL, PRD and qNOX significantly changed after noxious stimulation
  • PRD had the strongest correlation with varying remifentanil concentrations
  • ANI, NOL and qNOX showed no significant correlation with remifentanil concentrations

Observational data: associations, not effects.

Further findings

Raw EEG power spectral density after noxious stimulus in patients with low PRD

Significant increase in power in high EEG frequencies around 25 Hz and decreased power in alpha range (8-12 Hz)

Original publication

Cortical, subcortical, brainstem and autonomic responses to nociception under total intravenous anesthesia. J Clin Anesth. Published 12 April 2025. doi:10.1016/j.jclinane.2025.111825

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.