Respiratory failure & ventilation

Development and validation of VentPilot: an AI-based recommendation system for mechanical ventilation

J Intensive CarePublished Development and validation of VentPilot: an AI-based recommendation system for mechanical ventilation

Authors' conclusion

In multicenter retrospective validation cohorts, fitted Q-evaluation estimated higher returns for VentPilot than for observed clinician behavior under the prespecified reward function, while greater concordance between observed care and VentPilot recommendations was associated with more favorable clinical outcomes. Further clinical evaluation is warranted to establish VentPilot's safety, usability, and clinical impact.

Study context

Population
Mechanically ventilated adults at Seoul National University Hospital (SNUH) and Mayo Clinicderivation cohort 3,002 · internal validation cohort 283 · external validation cohort 1,011
Participants
4,296 mechanically ventilated adults
Comparison
Estimated return of VentPilot relative to observed clinician behavior under the prespecified reward function; patients with higher versus lower concordance between observed ventilator settings and VentPilot recommendations
Outcome
Overall reward (fitted Q-evaluation, prespecified reward function)
Methodological detailsoffline reinforcement learning, multicenter retrospective validation cohorts, fitted Q-evaluation, inverse probability-weighted analysis
  • Offline reinforcement learning
  • Multicenter retrospective validation cohorts
  • Fitted Q-evaluation
  • Inverse probability-weighted analysis

Recommendations

As reported in the abstract

Estimate (95% CI)
VentPilot vs observed clinician behavior
difference in overall reward(higher with a), internal validation cohort 1.6 (0.8–2.5)
VentPilot vs observed clinician behavior
difference in overall reward(higher with a), external validation cohort 1.3 (0.6–2.0)

Further findings

OutcomeEstimate
Ventilator-free days · within 28 daysHigher concordance vs lower concordance · inverse probability-weighted analysesmean difference (more with a), internal validation cohort 5.0 days (95% CI 2.4–7.6)
Ventilator-free days · within 28 daysHigher concordance vs lower concordance · inverse probability-weighted analysesmean difference (more with a), external validation cohort 3.1 days (95% CI 1.7–4.6)

28-day mortality and ICU length of stay

Higher concordance associated with lower 28-day mortality and shorter ICU length of stay

Original publication