Cardiothoracic & vascular anesthesia

The Diagnostic Accuracy of EXTEM and HEPTEM Clotting Times Versus Standard Laboratory Tests in Cardiac Surgical Patients With and Without Normal FIBTEM Values

J Cardiothorac Vasc AnesthPublished Diagnostic accuracy study

Authors' conclusion

EXTEM CT >80 seconds and HEPTEM CT >280 seconds have high sensitivities and NPVs for INR >2.0, which would effectively "rule out" INR >2.0 as a cause for excessive bleeding. However, the low specificities and PPVs indicate they would be less effective in ruling it in. INTEM CT >205 seconds had low PPV and NPV in identifying aPTT >38.5 seconds.

Study context

Population
Cardiac surgical patients, measured post-heparin reversal after CPB
Participants
176 patients
Comparison
EXTEM, INTEM and HEPTEM clotting times (CTs) vs laboratory international normalized ratio (INR) and activated partial thromboplastin time (aPTT) as reference standards
Outcome
Sensitivity, specificity, PPV and NPV of ROTEM CTs for INR ≥2.0 and aPTT ≥38.5 seconds
Follow-up
Post-heparin reversal after CPB
Methodological detailsretrospective, tertiary referral hospital
  • Retrospective
  • Tertiary referral hospital

Performance

As reported in the abstract

Diagnostic accuracy (all patients)
StrategySensitivitySpecificityPPVNPV
EXTEM CT >80 seconds1.000.250.171.00
HEPTEM CT >280 seconds0.910.380.180.97
INTEM CT >205 seconds0.970.110.570.75

Sensitivity

EXTEM CT >80 seconds1.00
HEPTEM CT >280 seconds0.91
INTEM CT >205 seconds0.97

Specificity

EXTEM CT >80 seconds0.25
HEPTEM CT >280 seconds0.38
INTEM CT >205 seconds0.11

PPV

EXTEM CT >80 seconds0.17
HEPTEM CT >280 seconds0.18
INTEM CT >205 seconds0.57

NPV

EXTEM CT >80 seconds1.00
HEPTEM CT >280 seconds0.97
INTEM CT >205 seconds0.75
Prevalence of INR ≥2.0
13%

Further findings

Diagnostic accuracy, subset with normal FIBTEM A5 (>6 mm) (subgroup)

Values similar to all patients

Original publication

The Diagnostic Accuracy of EXTEM and HEPTEM Clotting Times Versus Standard Laboratory Tests in Cardiac Surgical Patients With and Without Normal FIBTEM Values. J Cardiothorac Vasc Anesth. Published 27 June 2024. doi:10.1053/j.jvca.2024.06.031

Composed by AI from the published abstract and checked against it. How Briefs are made →