Respiratory failure & ventilation

Effects of Analysis Delay on pH , pO 2 , pCO 2 , Bicarbonate, Glucose, Lactate, Electrolytes, and Other Arterial Blood Gas Variables

Acta Anaesthesiol ScandPublished Methodological study

Authors' conclusion

According to our results, changes in the blood gas variables did not exceed the predefined thresholds for clinical relevance during the first 30 min after sample collection.

Study context

Population
Patients with arterial blood gas (ABG) samplesfinal analysis
Participants
80 patients
Comparison
ABG analysis delayed up to 120 min vs immediate analysis
Outcome
Time point at which the first ABG variable exceeded a predefined clinically acceptable threshold
Methodological detailstwo types of blood gas analyzers, repeated measurements at 0, 5, 10, 20, 30, 45, 60, and 120 min
  • Two types of blood gas analyzers
  • Repeated measurements at 0, 5, 10, 20, 30, 45, 60, and 120 min

Main finding

As reported in the abstract

  • First variable to exceed the threshold: pO2, increased above it after 45 min on both analyzers
  • At 30 min, all variable changes within the predetermined range for clinical relevance

Original publication

Effects of Analysis Delay on pH , pO 2 , pCO 2 , Bicarbonate, Glucose, Lactate, Electrolytes, and Other Arterial Blood Gas Variables. Acta Anaesthesiol Scand. Published 7 May 2025. doi:10.1111/aas.70049