Respiratory failure & ventilation

Electric impedance tomography-guided positive end-expiratory pressure (PEEP) titration reduces mechanical power in ARDS: a randomized crossover pilot trial

Crit CarePublished Randomised controlled trial

Primary result · Mechanical powerResult — go to the resultMean difference - 4.36 J/min 95% CI - 6.7, - 1.95

Authors' conclusion

In patients with moderate-severe acute respiratory distress syndrome, EIT-guided PEEP titration reduces mechanical power mainly through a reduction in elastic-dynamic power.

Study context

Population
Patients with moderate-severe ARDS on mechanical ventilation
Comparison
Electric impedance tomography (EIT)-guided PEEP selection vs High-PEEP/FiO2 table
Primary endpoint
Change in mechanical power after each PEEP selection strategy
Methodological detailscrossover, pilot, single-centre
  • Crossover
  • Pilot
  • Single-centre

Primary result

Mechanical power

Mean difference

- 4.36 J/min

95% CI - 6.7, - 1.95

P = 0.002

As reported in the abstract

Secondary outcomes

OutcomeEstimateP value
4ΔP + RR indexdifference - 11.42 J/min (95% CI - 19.01, - 3.82)P = 0.007
Elastic-dynamic powerdifference - 1.61 J/min (CI - 2.99, - 0.22)P = 0.027
Set PEEPchange - 2 cmH2OP = 0.046
Driving pressurechange - 2.92 cmH2OP = 0.003
Peak pressurechange - 6.25 cmH2OP = 0.003
Plateau pressurechange - 4.53 cmH2OP = 0.006
Static respiratory system compliancechange + 7.93 ml/cmH2OP = 0.008

Elastic-static and resistive powers

Unchanged

Original publication

Electric impedance tomography-guided PEEP titration reduces mechanical power in ARDS: a randomized crossover pilot trial. Crit Care. Published 17 January 2023. doi:10.1186/s13054-023-04315-x

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.