Evaluating the effects of continuous veno-venous hemodiafiltration on O2 and CO2 removal and energy expenditure measurement using indirect calorimetry

Ann Intensive CarePublished Prospective observational study

Authors' conclusion

CVVHDF may significantly alter QCO₂ levels without affecting QO₂, influencing the REE and RQ results measured by IC. However, the impact on REE is not clinically significant, and the REE value obtained via IC is closer to the true REE than that estimated using the Harris-Benedict equation.

Study context

Population
Patients with sepsis undergoing continuous veno-venous hemodiafiltration (CVVHDF)
Exposure
Downstream vs Upstream
Outcome
Effects of CVVHDF on O₂ and CO₂ removal (QCO₂, QO₂ before and after the filter) and accuracy of REE measurement using IC
Methodological detailssingle-center
  • Single-center

Main finding

As reported in the abstract

QCO₂ across the filter

P < 0.0001

Observational data: associations, not effects.

Further findings

OutcomeValuesP value
REE: true vs measured (IC) vs estimated (Harris-Benedict)True REE vs Measured REE · significantly differentTrue REE mean 1774.28 (SD 438.20) kcal/day · Measured REE mean 1758.59 (SD 434.06) kcal/day · Estimated REE mean 1619.36 (SD 295.46) kcal/dayP = 0.0029
REE: true vs measured (IC) vs estimated (Harris-Benedict)True REE vs Estimated REE · significantly differentP = 0.0475
RQ: measured vs trueSignificant differenceMeasured RQ mean 0.693 (SD 0.118) · True RQ mean 0.731 (SD 0.121)P < 0.0001

Original publication

Evaluating the effects of continuous veno-venous hemodiafiltration on O2 and CO2 removal and energy expenditure measurement using indirect calorimetry. Ann Intensive Care. Published 11 January 2025. doi:10.1186/s13613-025-01426-2