Pediatric anesthesia & critical care

Evaluation of quality of care in neonatal anesthesia using a bundle of intraoperative parameters

Paediatr AnaesthPublished Retrospective observational study

Authors' conclusion

Although a median of six out of the seven selected intraoperative parameters were monitored during gastroschisis repair, only two of them (oxygen saturation and heart rate) were maintained within the pre-defined range more than 80% of the time.

Study context

Population
Neonates undergoing gastroschisis surgery at Caen University Hospital (2009–2020)
Participants
53 gastroschisis surgeries
Outcome
Absolute number of 7 intraoperative parameters monitored during anaesthesia
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Number of intraoperative parameters monitored (of 7)

Median number of parameters monitored [first-third Q]

6

5–6

Range (min-max)

4-7

Observational data: associations, not effects.

Further findings

Frequency of monitoring of each parameter

Temperature monitored
38%
Glycemia monitored
66%
Natremia monitored
68%
Arterial BP, heart rate, end-tidal CO2, oxygen saturation (automatically recorded): no missing data

Parameter maintained within pre-defined range

Oxygen saturation
96%
Heart rate
81%
BP
28%
Temperature
30%

Original publication

Evaluation of quality of care in neonatal anesthesia using a bundle of intraoperative parameters. Paediatr Anaesth. Published 9 July 2023. doi:10.1111/pan.14719

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.