Pediatric anesthesia & critical care

Hemodynamic Impact of Mechanical Ventilation in Anesthetized Patients With Cavopulmonary Connection: A Physiologic Crossover Study

J Cardiothorac Vasc AnesthPublished Prospective crossover clinical study

Main finding · Cardiac indexResult — go to the resultMean difference 0.6 L/min/m²

Authors' conclusion

In anesthetized Glenn and Fontan patients with secured airways, spontaneous ventilation produces a superior hemodynamic profile compared with mechanical ventilation.

Study context

Population
Anesthetized children with cavopulmonary (Glenn or Fontan) anastomosis undergoing elective cardiac catheterizationcrossover
Participants
35 children
Exposure
Spontaneous breathing vs mechanical ventilation under GA
Outcome
Cardiac index
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Mean difference

0.6 L/min/m²

P = 0.022

Observational data: associations, not effects.

Further findings

OutcomeMean difference (mmHg)P value
Atrial pressure1.9P < 0.001

Pulmonary vascular resistance, transpulmonary gradient, Qp:Qs

Did not differ significantly between ventilation methods

Original publication

Hemodynamic Impact of Mechanical Ventilation in Anesthetized Patients With Cavopulmonary Connection: A Physiologic Crossover Study. J Cardiothorac Vasc Anesth. Published 31 July 2025. doi:10.1053/j.jvca.2025.07.037

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.