Cardiothoracic & vascular anesthesia

Intraoperative glycemic protocol calculator: automation in the OR

J Clin Monit ComputPublished Retrospective cohort study

Authors' conclusion

Implementation of the IGPC significantly improved real-time adherence to intraoperative glycemic control protocols without increasing adverse glycemic events.

Study context

Population
Adults undergoing CABG and/or valve surgery requiring CPB, tertiary care academic hospital
Participants
143 adults
Exposure
Intraoperative Glycemic Protocol Calculator (IGPC) implementation vs pre-intervention
Outcome
Protocol adherence (appropriate insulin administration within five minutes of glucose measurement)
Methodological detailssingle-centre, before-after (pre- vs post-intervention)
  • Single-centre
  • Before-after (pre- vs post-intervention)

Main finding

As reported in the abstract

Protocol adherence by intraoperative phase

Pre-CPB adherence

65.5% to 80.2%

On-CPB adherence

53.0% to 75.1%

Post-CPB adherence

34.8% to 58.8%

Observational data: associations, not effects.

Safety

Severe hypoglycaemia

P = 0.772

Intraoperative hyperglycaemia

P = 0.995

Original publication

Intraoperative glycemic protocol calculator: automation in the OR. J Clin Monit Comput. Published 20 November 2025. doi:10.1007/s10877-025-01374-z