Respiratory failure & ventilation

Is Electrical Impedance Tomography (EIT)-guided positive end-expiratory pressure titration for optimizing PEEP in ARDS the white elephant in the room? A systematic review with meta-analysis and trial sequential analysis

J Clin Monit ComputPublished Systematic review and meta-analysis

Authors' conclusion

EIT-guided individualized PEEP titration is a novel modality

Study context

Population
Adult ARDS patients
Participants
515 patients · 5 cohort studies · 2 RCTs
Comparison
EIT-guided PEEP titration vs conventional methods
Outcome
Mortality
Methodological detailstrial sequential analysis
  • Trial sequential analysis

Pooled result

As reported in the abstract

Overall reduced risk of mortality with EIT-guided PEEP titration: RR

0.68

95% CI 0.49 to 0.95; I2 = 0%

Further pooled results

Dynamic compliance

Better dynamic compliance with EIT-guided PEEP titration: MD
3.46 (95% CI 1.59 to 5.34; I2 = 0%)
  • Required information size achieved (trial sequential analysis)

PaO2/FiO2 ratio

No significant difference in PaO2/FiO2 ratio: MD
6.5 (95% CI −13.86 to 26.76; I2 = 74%)
  • Required information size not achieved (trial sequential analysis)

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Is EIT-guided positive end-expiratory pressure titration for optimizing PEEP in ARDS the white elephant in the room? A systematic review with meta-analysis and trial sequential analysis. J Clin Monit Comput. Published 15 April 2024. doi:10.1007/s10877-024-01158-x

Composed by AI from the published abstract and checked against it. How Briefs are made →