Respiratory failure & ventilation

Limitations of SpO2 / FiO2-ratio for classification and monitoring of acute respiratory distress syndrome—an observational cohort study

Crit CarePublished Observational cohort study

Authors' conclusion

The use of SpO2/FiO2 interchangeably with PaO2/FiO2 for severity classification and monitoring of ARDS is limited by its inadequate trending ability and high dependence on FiO2 settings, which may influence treatment decisions and patient selection in clinical trials.

Study context

Population
Acute respiratory distress syndrome (ARDS) patients (Berlin criteria or ICD 9/10-codes) from three high-resolution ICU databases
Participants
708 patients · 3 ICU databases
Exposure
SpO2/FiO2 vs PaO2/FiO2 for ARDS severity classification and monitoring
Outcome
ARDS severity classification by SpO2/FiO2 vs PaO2/FiO2 and tracking of disease progression
Methodological detailsmulticentre databases (ICU Cockpit, MIMIC-IV, SICdb), time-matched datapoints
  • Multicentre databases (ICU Cockpit, MIMIC-IV, SICdb)
  • Time-matched datapoints

Main finding

As reported in the abstract

ARDS severity misclassification by SpO2/FiO2

Datapoints misclassified by SpO2/FiO2

33%

Misclassified datapoints classified as more severe

84%

Observational data: associations, not effects.

Further findings

Tracking change in ARDS severity

High dependence of SpO2/FiO2 on FiO2 settings; change in severity tracked in less than 20% of events

Original publication

Limitations of SpO2 / FiO2-ratio for classification and monitoring of acute respiratory distress syndrome—an observational cohort study. Crit Care. Published 19 February 2025. doi:10.1186/s13054-025-05317-7

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.