Cardiothoracic & vascular anesthesia

PERSUADE Survey—PERioperative AnestheSia and Intensive Care Management of Left VentricUlar Assist DevicE Implantation in Europe and the United States

J Cardiothorac Vasc AnesthPublished Cross-sectional study

Authors' conclusion

Although the perioperative practice of care for patients undergoing LVAD implantation differs in several aspects between Europe and the US, there were no perceived differences in early postoperative complications.

Study context

Population
Left ventricular assist device (LVAD) implantation centres in Europe and the UScentres completing survey
Participants
73 vs 60
Exposure
European vs US LVAD centres
  • Europen = 73
  • USn = 60
Outcome
Survey completion
Methodological detailsonline survey, prospective data analysis, 91 of 202 European and 93 of 195 US centres received the survey link
  • Online survey
  • Prospective data analysis
  • 91 of 202 European and 93 of 195 US centres received the survey link

Main finding

As reported in the abstract

Propofol used more often for maintenance in Europe
P < 0.001
Quantitative methods for defining right ventricular (RV) function reported more often by European than US centres
P < 0.05

Observational data: associations, not effects.

Safety

Early postoperative complications

No significant differences reported from European vs US centres

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

PERSUADE Survey—PERioperative AnestheSia and Intensive Care Management of Left VentricUlar Assist DevicE Implantation in Europe and the United States. J Cardiothorac Vasc Anesth. Published 18 October 2023. doi:10.1053/j.jvca.2023.10.013

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.