Pediatric anesthesia & critical care

Positive End-Expiratory Pressure and Atelectasis after Bronchial Blockade One-Lung Ventilation in Infants: A Randomized Controlled Study

J Cardiothorac Vasc AnesthPublished Randomised controlled trial

Authors' conclusion

In one-lung ventilation using bronchial blockers performed during thoracoscopic lobectomies in infants, applying PEEP at 5 to 6 cmH2O combined with 100% oxygen ventilation after the removal of the bronchial blocker until extubation was associated with improved oxygenation and did not appear to increase the risk of atelectasis during emergence from anesthesia.

Study context

Population
Infants <1 year, American Society of Anesthesiologists (ASA) I–II, with congenital cystic adenomatoid malformation undergoing thoracoscopic lobectomy with bronchial blocker one-lung ventilation (OLV)
Participants
69 vs 69
Comparison
Group A vs Group B
  • Group An = 69reference
  • Group Bn = 69
Primary endpoint
Atelectasis during emergence from anesthesia
Methodological detailssingle teaching hospital, Infants operated June 2024 to December 2024
  • Single teaching hospital
  • Infants operated June 2024 to December 2024

Primary result

As reported in the abstract

Atelectasis after extubation (lung ultrasound score 3 and chest radiography atelectasis score 3, both lungs) · after extubation
Proportions with lung ultrasound scores of 3 and chest radiography atelectasis scores of 3 lower in Group B vs Group A
p < 0.05

Further findings

Hypoxemia after extubation (SpO2 < 90%)

P < 0.05

Oxygenation index, alveolar-arterial oxygen differential pressure, SpO2 at completion of surgery (T1)

No significant differences between groups
P > 0.05

Oxygenation index, PaO2, alveolar-arterial oxygen differential pressure, lowest SpO2 within 30 min after extubation · T2 (30 minutes after extubation)

Oxygenation index and PaO2 greater, alveolar-arterial difference lower, lowest SpO2 better in Group B vs Group A
P < 0.05

Time from bronchial blocker removal to extubation

Shorter in Group B than in Group A
P < 0.05

Duration of oxygen administration after extubation

Shorter in Group B than in Group A
P < 0.05

Perioperative hemodynamics, duration of operation, postoperative hospital LOS

No significant differences between groups
P > 0.05

Correlation of lung ultrasound scores with chest radiographic atelectasis score

Statistically significant correlation in both groups
P < 0.05

Original publication

Positive End-Expiratory Pressure and Atelectasis after Bronchial Blockade One-Lung Ventilation in Infants: A Randomized Controlled Study. J Cardiothorac Vasc Anesth. Published 16 June 2025. doi:10.1053/j.jvca.2025.06.025

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.