Processed electroencephalogram-guided anesthesia and its impact on postoperative delirium and perioperative efficiency: A systematic review and meta-analysis
Authors' conclusion
Across 87 RCTs, pEEG-guided monitoring utilizing multiple device types improved perioperative efficiency and reduced POD compared with not using pEEG. Evidence is strongest for BIS; further well-reported trials are needed to delineate device-specific effects.
Study context
- Population
- Adults undergoing surgical, endoscopic, or dental procedurespatients in 87 RCTs
- Participants
- 30,611 adults
- Comparison
- Processed electroencephalography (pEEG)-guided with non-pEEG-guided anesthesia
- pEEGn = 13,586
- non-pEEGn = 17,025reference
- Outcome
- Primary outcomes: anesthetic drug use (TIVA and volatile agents) and postoperative delirium (POD ≤10 days)
Methodological detailsrandom-effects models, subgroup analyses by pEEG technology
- Random-effects models
- Subgroup analyses by pEEG technology
Pooled result
As reported in the abstract
Primary outcomes: anesthetic drug use (TIVA and volatile agents) and postoperative delirium (POD ≤10 days)
pEEG vs non-pEEGRR, POD (95% CI)P value
Risk of POD decreased by 27%
0.73(0.63–0.84)
P < 0.01- Reduced with pEEG
- SMD, propofol use −0.42 (95% CI −0.74 to −0.10); P = 0.01
- Reduced with pEEG
- SMD, volatile anesthetic use −1.27 (95% CI −1.88 to −0.66); P < 0.01
Further pooled results
| Outcome | MD (min) (95% CI) | P value | |
|---|---|---|---|
| Extubation timeFavored pEEG · secondary outcome | −2.90 (−3.64 to −2.16) | P < 0.01 | |
| Wake-up timeFavored pEEG · secondary outcome | −1.83 (−2.42 to −1.25) | P < 0.01 | |
| Time to orientationFavored pEEG · secondary outcome | −4.11 (−6.99 to −1.23) | P < 0.01 | |
| PACU length of stayFavored pEEG · secondary outcome | −2.81 (−4.66 to −0.96) | P < 0.01 | |
| −10−505Difference, min (linear scale) |
Subgroup analyses by pEEG technology (subgroup)
- Subgroup analyses suggested benefits were most consistently observed for BIS; estimates for Entropy and SEDLine were less precise due to fewer studies.
Heterogeneity
- Heterogeneity was substantial for several outcomes.
Original publication
Processed electroencephalogram-guided anesthesia and its impact on postoperative delirium and perioperative efficiency: A systematic review and meta-analysis. J Clin Anesth. Published 30 October 2026. doi:10. 1016/ j. jclinane. 2026. 112351
Composed by AI from the published abstract and checked against it. How Briefs are made →