Pediatric anesthesia & critical care
Propofol in Exhaled Air and Plasma During Paedfusor Target‐Controlled Infusion in Children
Authors' conclusion
This exploratory study demonstrates that online monitoring of exhaled propofol during surgery is feasible in children. The Edmon provided estimates of CP comparable with those of the Paedfusor algorithm during maintenance of anaesthesia, but its use is limited by a complex setup and a 4-min time lag relative to plasma concentrations.
Study context
- Population
- Children undergoing propofol-based anaesthesia with the Paedfusor target-controlled infusion (TCI) modelchildren aged 3–10 years included
- Participants
- 26 children
- Exposure
- Exhaled Drug Monitor (Edmon) for online estimation of exhaled propofol concentrations (CA) as a proxy for plasma propofol concentrations (CP); relationships between Paedfusor-estimated concentrations (CE-P) and CP, and between CP and Bispectral Index (BIS)
- Outcome
- Time lag of CA behind CP
- Follow-up
- During maintenance of anaesthesia at a TCI target concentration of 3.0 μg mL-1
Methodological detailsexploratory
- Exploratory
Main finding
As reported in the abstract
CA lagged behind CP by
4 min
Observational data: associations, not effects.
Further findings
Pooled median absolute performance error · samples obtained at 20 and 30 min after induction
Estimation of CP from CA, at a delay of 4 min · During maintenance of anaesthesia at a TCI target concentration of 3.0 μg mL-1
- Slope (gain)
- 0.36 μg mL-1 ppb-1 (95% confidence interval [CI] 0.08 to 0.64, p = 0.015)
- Intercept (offset)
- 1.16 μg mL-1 (95% CI −0.52 to 2.84, p = 0.16)
- RSquare
- 0.63
CP higher than Paedfusor predictions
- At 20 min
- 19%
- At 30 min
- 16%
- At end of surgery
- 1%
BIS values and CP (exploratory analysis)
- BIS values decreased for each 1 μg mL-1 increase in CP by
- 4.8
- Exploratory analysis