Anaesthetic drugs & techniques

Reducing Volatile Anesthetic Waste Using a Commercial Electronic Health Record Clinical Decision Support Tool to Lower Fresh Gas Flows

Anesth AnalgPublished Interrupted time series study

Authors' conclusion

A commercial AIMS-based decision support tool can be adopted to change provider FGF management patterns and reduce volatile anesthetic consumption in a sustainable fashion.

Study context

Population
Anesthetic cases using sevoflurane or desflurane during maintenance of anesthesiasevoflurane 44,899 pre/26,911 post
Comparison
Postintervention vs Preintervention
Outcome
Mean FGF (L/min) and volatile agent consumption (mL/MAC-h)
Methodological detailssegmented regression, adjusted for potential confounding variables, before-after
  • Segmented regression
  • Adjusted for potential confounding variables
  • Before-after

Main finding

As reported in the abstract

Mean FGF (L/min) and volatile agent consumption (mL/MAC-h), segmented regression of interrupted time series · immediately after implementation of the intervention
Decrease in mean FGF, sevoflurane
0.6 L/min (95% CI, 0.6-0.6 L/min; P < .0001)
Decrease in mean FGF, desflurane
0.2 L/min (95% CI, 0.2-0.3 L/min; P < .0001)
Decrease in mL/MAC-h, sevoflurane
3.8 mL/MAC-h (95% CI, 3.6-4.1 mL/MAC-h; P < .0001)
Decrease in mL/MAC-h, desflurane
4.1 mL/MAC-h (95% CI, 2.6-5.6 mL/MAC-h; P < .0001)
Postintervention slopes for FGF and mL/MAC-h statistically less negative than preintervention slopes, sevoflurane
P < .0001
Postintervention slopes for FGF and mL/MAC-h statistically less negative than preintervention slopes, desflurane
P < .01

Further findings

Slopes of FGF and mL/MAC-h, post vs preintervention

Postintervention slopes statistically less negative than preintervention slopes, sevoflurane
P < 0.0001
Postintervention slopes statistically less negative than preintervention slopes, desflurane
P < 0.01

Original publication

Reducing Volatile Anesthetic Waste Using a Commercial Electronic Health Record Clinical Decision Support Tool to Lower Fresh Gas Flows. Anesth Analg. Published 4 November 2022. doi:10.1213/ane.0000000000006242

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.