Hemodynamics, fluids & transfusion

Revisiting the fluid challenge and stroke volume optimisation after induction of general anaesthesia

Ann Intensive CarePublished Secondary analysis of a randomised clinical trial

Authors' conclusion

Differences in effectiveness between crystalloid and colloid fluid when providing repeated FCs increase the risk of false negative indications of fluid non-responsiveness when crystalloid is used.

Study context

Population
Patients just after induction of GA
Participants
111 participants
Comparison
Crystalloid vs colloid fluid challenges

Primary result

As reported in the abstract

SV increase after three FCs

Crystalloid

2.5%

median

Colloid

29.2%

median

P < 0.001

Further findings

BV expansion

P < 0.001

OutcomeCrystalloidColloidP value
ΔSV%/ΔBV% ratio0.120.98P < 0.001

Cardiac response to first fluid challenge (FC) and oxygen delivery

Falsely low in both groups due to reflex redistribution of interstitial fluid into the circulation after anaesthetic induction

Original publication

Revisiting the fluid challenge and stroke volume optimisation after induction of general anaesthesia. Ann Intensive Care. Published 22 May 2026. doi:10.1016/j.aicoj.2026.100093

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.