Regional anesthesia

Ultrasound-guided stellate ganglion block in patients with electrical storm: A single-center case series

J Clin AnesthPublished Case series

Main finding · Sustained ventricular arrhythmias (number) and ATP or shocks, within 24 h before vs after first SGBResult — go to the resultMedian difference −5.5 95 % CI −9.5 to −3.0

Authors' conclusion

SGB appears to be a safe and effective treatment that may provide temporary stabilization between the onset of ES and catheter ablation, while also aiding in the management of persistent ES post-catheter ablation and newly developed ES following cardiac surgery.

Study context

Population
Patients with electrical storm (ES) treated with ultrasound-guided stellate ganglion block (SGB), July 2023–July 2024
Participants
20 patients
Exposure
Before vs after SGB
Outcome
Changes in sustained ventricular arrhythmias and anti-tachycardia pacing (ATP) or defibrillation shocks; effectiveness = ≥ 50 % reduction post-block
Follow-up
24 h before and after SGB
Methodological detailssingle-centre, 60 % persistent ES after catheter ablation, 20 % diagnosed on emergency admission, 15 % ES after cardiac surgery
  • Single-centre
  • 60 % persistent ES after catheter ablation, 20 % diagnosed on emergency admission, 15 % ES after cardiac surgery

Main finding

As reported in the abstract

Sustained ventricular arrhythmias (number) and ATP or shocks, within 24 h before vs after first SGB · 24 h after first SGB

Median difference

−5.5

95 % CI −9.5 to −3.0

P = 0.001

By group

Before SGB

4.5

median · IQR 3.0–13.0

After first SGB

0

median · IQR 0–1.0

After first SGB vs Before SGB
median difference −5.5 (95 % CI −9.5 to −3.0); P = 0.001
ATP or shocks, median (IQR) before SGB
1.5 (0-4.0)
ATP or shocks, median (IQR) after first SGB
0 (0-0.75)
ATP or shocks, median difference
−2.0 (95 % CI −4.5 to −0.5, p = 0.011)
ATP or shocks, effectiveness rate
78.6 %

Observational data: associations, not effects.

Further findings

OutcomeAfter last SGBMedian difference (95 % CI)P value
Sustained ventricular arrhythmias (number) and ATP or shocks, within 24 h after last SGB vs baselineSustained ventricular arrhythmiasmedian 0 (IQR 0–0.75)−5.0 (−10.5 to −2.5)P = 0.004
Effectiveness rate80.0 %
Sustained ventricular arrhythmias (number) and ATP or shocks, within 24 h after last SGB vs baseline — ATP or shock events, median (IQR) at baseline
1.5 (0-4.0)
Sustained ventricular arrhythmias (number) and ATP or shocks, within 24 h after last SGB vs baseline — ATP or shock events, median (IQR) after last SGB
0 (0-0)
Sustained ventricular arrhythmias (number) and ATP or shocks, within 24 h after last SGB vs baseline — ATP or shock events, median difference
−1.75 (95 % CI −12.5 to −0.5, p = 0.028)
Sustained ventricular arrhythmias (number) and ATP or shocks, within 24 h after last SGB vs baseline — ATP or shock events, effectiveness rate
86.7 %

Safety

Minor complications after SGB

Patients with minor complications
10 %
Hoarseness
1
Phrenic nerve block
1
Both fully recovered without sequelae

Original publication

Ultrasound-guided stellate ganglion block in patients with electrical storm: A single-center case series. J Clin Anesth. Published 2 May 2025. doi:10.1016/j.jclinane.2025.111850

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.