Anesthetic drugs & techniques

Variability of predicted propofol concentrations and measured sevoflurane concentrations during general anaesthesia: a single-centre retrospective cohort study

Br J AnaesthPublished Retrospective cohort study

Authors' conclusion

Improvements in prediction accuracy of pharmacokinetic models beyond that of those already in clinical use are unlikely to reduce variability in target anaesthetic concentrations across patients in clinical practice.

Study context

Population
Surgical procedures >1 h under GA with sevoflurane or propofol per institutional protocol
Participants
2,280 surgical procedures
Exposure
Sevoflurane vs propofol target-controlled infusion (TCI), titrated to BIS 40-60
Outcome
Variability of required anaesthetic concentrations (normalized concentration range)
Follow-up
30 min after skin incision
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Normalized concentration range · 30 min post-incision

Sevoflurane

0.89

99% CI 0.78–0.99

Propofol TCI

0.93

99% CI 0.87–1.02

Observational data: associations, not effects.

Further findings

OutcomeSevofluranePropofol TCI
Achieved BIS range (titration performance) · 30 min post-incision30 (99% CI 28–33)31 (99% CI 27–36)

Achieved BIS range (titration performance) · 30 min post-incision

Not significantly different

Original publication

Variability of predicted propofol concentrations and measured sevoflurane concentrations during general anaesthesia: a single-centre retrospective cohort study. Br J Anaesth. Published 3 August 2023. doi:10.1016/j.bja.2023.06.064

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.