Cardiothoracic & vascular anesthesia

Direct Reinfusion of Unwashed Shed Autologous Blood During Thoracoabdominal Aortic Aneurysm Repair: A Retrospective Analysis

Anesth AnalgPublished Retrospective cohort study

Authors' conclusion

For patients undergoing open TAAA repair, larger reinfusion volumes of unwashed SAB were not associated with greater odds of major early postoperative complications.

Study context

Population
Patients undergoing open thoracoabdominal aortic aneurysm repair who received unwashed shed autologous blood, 2007–2021
Participants
972 consecutive patients
Exposure
Larger vs smaller reinfusion volumes of unwashed shed autologous blood
Outcome
Composite outcome of adverse events
Follow-up
30 days
Methodological detailsprospectively maintained database, single-centre, consecutive patients, multivariable logistic regression
  • Prospectively maintained database
  • Single-centre
  • Consecutive patients
  • Multivariable logistic regression

Main finding

As reported in the abstract

Composite adverse events
  • Greater reinfusion volumes of unwashed shed autologous blood (SAB) not associated with greater odds of composite adverse events
  • Multivariable logistic regression

Observational data: associations, not effects.

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Direct Reinfusion of Unwashed Shed Autologous Blood During Thoracoabdominal Aortic Aneurysm Repair: A Retrospective Analysis. Anesth Analg. Published 14 February 2025. doi:10.1213/ane.0000000000007103

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.