Anesthetic drugs & techniques

Effects of low tidal volume on dynamic arterial elastance in patients undergoing laparoscopic surgery

J Clin Monit ComputPublished Prospective observational study

Authors' conclusion

The reduction in tidal volume had a clinically negligible effect on Eadyn.

Study context

Population
Patients undergoing laparoscopic surgery with MAP < 65 mmHg and SVV > 10% after start of intra-abdominal insufflation
Participants
46 patients
Exposure
Tidal volume 6 vs 8 mL/kg predicted body weight (PBW) (Eadyn); MAP responders vs non-responders to fluid challenge
  • MAP respondersn = 35
  • MAP non-respondersn = 11reference
Outcome
Effect of tidal volume reduction from 8 to 6 mL/kg PBW on dynamic arterial elastance (Eadyn)

Main finding

As reported in the abstract

Change in Eadyn after tidal volume reduction

Bland-Altman mean difference in Eadyn, before vs after tidal volume reduction

- 0.004

Bland-Altman 95% limits of agreement

- 0.285 to + 0.278

Observational data: associations, not effects.

Further findings

PPV and SVV change after tidal volume reduction

PPV decrease
- 19.4 ± 11%
SVV decrease
- 19.7 ± 9.9%
  • Both decreased significantly; magnitude of decrease differed

Eadyn prediction of MAP responsiveness to fluid challenge

AUC at 8 mL/kg PBW
0.514
AUC at 6 mL/kg PBW
0.508
  • Failed to predict MAP responsiveness

Original publication

Effects of low tidal volume on dynamic arterial elastance in patients undergoing laparoscopic surgery. J Clin Monit Comput. Published 9 October 2025. doi:10.1007/s10877-025-01364-1

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.