Hemodynamics, fluids & transfusion

Evaluating the Utility of Portal Vein Pulsatility Index for Detecting Fluid Unresponsiveness in the Intensive Care Unit

J Cardiothorac Vasc AnesthPublished Diagnostic accuracy study

Authors' conclusion

Although PVP has limited value as the sole indicator for fluid management decisions, it can be used as a stopping rule or combined with other diagnostic tests to improve the accuracy of fluid responsiveness assessment.

Study context

Population
ICU patients evaluated by ultrasonography of portal vein flow before fluid expansion; non-responders = <15% increase in left ventricle outflow tract velocity-time integral after 500 mL Ringer LactateJanuary–October 2022
Participants
63 patients
Outcome
Capacity of PVP to detect fluid unresponsiveness
Methodological detailsretrospective, single-centre, Tertiary medical-surgical ICU, Buenos Aires, Argentina
  • Retrospective
  • Single-centre
  • Tertiary medical-surgical ICU, Buenos Aires, Argentina

Performance

As reported in the abstract

Fluid unresponsiveness
Test or modelAUC (95% CI)ThresholdSensitivity (95% CI)Specificity (95% CI)PPVNPV (95% CI)
PVP0.708 (0.580 to 0.816)>32%30.8% (17% to 47.6%)100% (85.8 to 100)100%47.1% (41.9% to 52.3%)

PVP

AUC (95% CI)0.708 (0.580 to 0.816)
Threshold>32%
Sensitivity (95% CI)30.8% (17% to 47.6%)
Specificity (95% CI)100% (85.8 to 100)
PPV100%
NPV (95% CI)47.1% (41.9% to 52.3%)

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Evaluating the Utility of Portal Vein Pulsatility Index for Detecting Fluid Unresponsiveness in the Intensive Care Unit. J Cardiothorac Vasc Anesth. Published 25 May 2023. doi:10.1053/j.jvca.2023.05.039

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.