Cardiothoracic & vascular anesthesia

Monitoring systemic ventriculoarterial coupling after cardiac surgery using continuous transoesophageal echocardiography and deep learning

J Clin Monit ComputPublished Prospective observational study

Authors' conclusion

In conclusion, continuous monitoring using autoMAPSE in the first two postoperative hours reflected ventriculoarterial coupling as well as peak ProBNP and TnT during the subsequent 24 h.

Study context

Population
Patients immediately after cardiac surgery monitored with continuous TOE and deep learning (autoMAPSE)
Participants
50 participants
Outcome
Relationship between autoMAPSE and ventriculoarterial coupling (Ea/Ees-ratio) and postoperative cardiac biomarkers
Follow-up
First 120 min after surgery

Main finding

As reported in the abstract

Correlations of autoMAPSE

autoMAPSE vs Ea/Ees-ratio, rho

- 0.61

autoMAPSE vs peak postoperative ProBNP, rho

- 0.46

autoMAPSE vs peak postoperative troponin-T (TnT), rho

- 0.29

Observational data: associations, not effects.

Original publication

Monitoring systemic ventriculoarterial coupling after cardiac surgery using continuous transoesophageal echocardiography and deep learning. J Clin Monit Comput. Published 17 July 2025. doi:10.1007/s10877-025-01328-5

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.