Respiratory failure & ventilation

Rapid non-invasive measurement of mitochondrial oxygen tension after microneedle pre-treatment: a feasibility study in human volunteers

J Clin Monit ComputPublished Physiological feasibility study

Authors' conclusion

We demonstrate that pre-treatment with microneedling before topical application of 5-aminolevulinic acid enables obtaining a reliable and accurate mitoPO2 signal at least an hour faster than on untreated skin in our population of human volunteers.

Study context

Population
Healthy human volunteers
Participants
9 volunteers
Comparison
Microneedled vs Untreated
Outcome
Time-to-sufficient mitoPO2 signal after topical ALA administration
Methodological detailswithin-subject comparison, mitoPO2 varied using different FiO2 after induction
  • Within-subject comparison
  • mitoPO2 varied using different FiO2 after induction

Main finding

As reported in the abstract

Time to reliable signal after topical ALA

P = 0.02

Further findings

OutcomeEstimate
Agreement of mitoPO2 between microneedling and untreated skinMicroneedling vs Untreatedintraclass correlation 0.892 (95% CI 0.821–0.936)
Agreement of mitoVO2 between microneedling and untreated skinMicroneedling vs Untreated · poor agreementICC 0.316 (CI 0.04–0.55)

Original publication

Rapid non-invasive measurement of mitochondrial oxygen tension after microneedle pre-treatment: a feasibility study in human volunteers. J Clin Monit Comput. Published 26 December 2024. doi:10.1007/s10877-024-01249-9

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.